  Detailed PIAB Load and Force Measurement Data:  
  Crane and Hoist Overload Protection  
  Bulk Handling Load Control  
  Tension Measurement in Suspension Cables  
  Force Measurement and Load Indicators  
PIAB Pin SLC & Transducer Amplifier LCA
     
Back
  to Bulk Handling Load Control Main Page
     
 
PIAB is an ISO 9001 Accredited Company

The Load Pin can be dimensioned to replace an existing shaft. The Load Pin/Transducer Amplifier are compatible with all Piab electronic systems for overload protection and load indication. The SLC and LCA are made for use in aggressive environments and fully conform to IP 67.
 
     
Range of Application  |  Function  |  LCA Transducer Amplifier for Current Signal Output  |  Technical Data SLC  |  Installation Example of Load Pin SLC  |  Technical Data LCA  |  Dimensions of Amplifier LCA
     
     
RANGE OF APPLICATION

When overload protection and/or load indication is to be installed in a conveyor/crane or other device, the SLC may be the ideal solution. The Load Pin can easily replace the existing shaft at an equalizing pulley or in other parts of the construction.

The Load Pin should be installed as close as possible to the force/load for best accuracy.

Both the Load Pin and the Amplifier are designed to withstand extreme environmental conditions for a long operation time.

     
     
     
FUNCTION

The Load Pin SLC is designed as a shaft. Built into the shaft is a number of foil-strain-gauges for sensing of the deformation of the shaft during exposure to load. Shear forces appear in the section between the support and the applied load. Those shear forces are relative to the load on the Load Pin. Since the strain-gauges are positioned in the centre of the Load Pin little or no influence is derived from bending or torsion forces. The strain gauges shall be fed with 10 V DC from Amplifier LCA. The strain gauges delivers a signal to the amplifier (mV/V). This is converted in the LCA Amplifier to a current signal of 4-20 mA which is extremely resistant to interference.

The Transducer Amplifier should be installed as close as possible to the Load Pin. The Load Pins can be designed within very wide limits for dimensions and capacities.

     
    Back to Top  
     
LCA TRANSDUCER AMPLIFIER FOR CURRENT SIGNAL OUTPUT

The Transducer Amplifier LCA, Art. No. 301281, is an instrument amplifier with "chopper"-input. An DC Power Supply (l0 V DC) for strain gauges is integrated with the Amplifier. The Amplifier converts the mV/V signal from the Transducer to a robust, standardized "Current Signal" (4-20 mA).

     
     
     
TECHNICAL DATA SLC

  Capacity   Minimum 500 kg
  Diameter   Minimum 20 mm
  Accuracy   Typical value approx. 1% of rated capacity for Load Pin in equalization pulley close to the load. (Installation-dependant).
  Material   High-tensile alloy steel
  International Protection Specification Class   IP 67, according to IEC 529
  Temperature Range   -20°C to +70°C
  Overload   Can occasionally be overloaded up to 100% of rated capacity.
  Safety Factor   5:1 (Guaranteed safety against rupture 5 times nominal load.)
  Cable   Length 5 m as standard
  Signal Output   0.5 to 1.5 m V/V
     
    Back to Top  
     
INSTALLATION EXAMPLE OF LEAD PIN SLC

     
     
     
TECHNICAL DATA LCA

  Transducer Input   For strain gauges of 350 ohm impedance, up to max. 4 each in parallel
  Temperature Range   -20°C to +70°C
  Power Supply   +15 to +30 V DC
  Current Drain   Max. 70 mA at full load on one load cell
  International Protection Specification Class   IP 67, according to IEC 529

 

     
     
     
DIMENSIONS OF AMPLIFIER LCA

     
    Back to Top  
     