Unirope Logo
Home Products Inspection and Services
Gray bar shadow
  Detailed PIAB Load and Force Measurement Data:  
  Crane and Hoist Overload Protection  
  Bulk Handling Load Control  
  Tension Measurement in Suspension Cables  
  Force Measurement and Load Indicators  
PIAB Craneweigher
     
Back
  to Crane and Hoist Overload Protection Main Page
     
 
PIAB is an ISO 9001 Accredited Company

The Piab Craneweigher is used for weighing and force measurement where the demands for accuracy, reliability and safety are high. The Piab Craneweigher is constructed for continuous service under the most severe conditions.
 
     
Range of Application  |  Function  |  Protection against Corrosion  |  Safety  |  Craneweigher for Remote Reading  |  Craneweigher with Contact Function  |  Chart  |  Technical Data
     
     
RANGE OF APPLICATION

The Piab Craneweigher is an all-weather instrument, equally suitable for use in or out of doors and may be supplied with or without remote-reading instruments for weighing and for measuring of mechanical forces.

The Piab Craneweigher is exceptionally well suited for measurements in breaking tests, as the max. load pointer remains at the breaking point or max. value reached.

     
    Back to Top  
     
FUNCTION

The pull rod operates the pointer through a spring loaded floating transmission mechanism. This allows the craneweigher to withstand very severe shock loads and rapid unloading.

The power absorbing element consists of specially made Belleville type spring washers, so designed as to be entirely free from wear.

The spring washers cannot be overloaded.

     
     
     
PROTECTION AGAINST CORROSION

The Piab Craneweigher is fully pressure tight and each instrument is pressure tested. No leakage is permitted. The external surfaces are zinc plated with clear chromate passivation. If the craneweigher is to be used in a very corrosive atmosphere, it can be epoxy lacquered.

     
     
     
SAFETY

Safety factor 5:1. (Guaranteed to withstand a load of 5 times full scale reading before rupture.) The resistance to rupture is tested by the National Swedish Institute for Materials Testing.

The craneweigher may be overloaded by 100% without impairing the accuracy.

The scale is protected by thick acrylic glass and a heavy duty removable wire shield.

The craneweighers, types WA-WG have drop-forged steel eye brackets (SIS 2174 St 52-3N acc. to DIN 17100, 50 D acc. to BS 4360); giving a guaranteed impact resistance to -4°F (-20°C).

The O-ring of the pull rod is protected by a neoprene rubber membrane.

On instantaneous unloading, e.g., breaking test, the return movement of the pull rod is retarded by a specially made spring washer.

The Piab Craneweigher is approved by the National Swedish Board of Occupational Safety and Health for integral connection in the carrying system of a lifting device and for weighing of test loads in connection with inspection.

     
    Back to Top  
     
CRANEWEIGHER FOR REMOTE READING

The Piab Craneweigher used for remote reading is supplied with a built-in precision potentiometer. The potentiometer is directly connected to the scale mechanism of the Piab instrument. The electrical resistance of the potentiometer varies in proportion to the load of the craneweigher. The resistance is indicated on a receiving instrument, calibrated individually and marked with the same serial number as the craneweigher. The electrical connections are made in the terminal box to a numbered connection block.

A craneweigher with potentiometer cannot be equipped with max. pointer.

If a craneweigher with potentiometer is delivered without receiving instrument, a resistance chart with at least 10 incremental values is included.

     
     
     
CRANEWEIGHER WITH CONTACT FUNCTION

The Piab Dynamometer can be equipped with a built-on adjustable contact head. Using a microswitch, which is directly influenced by the pull rod, the dynamometer gives an electrical contact function at a previously set value. For the types MA-O the extension to the body length is about 3.15/16" (100 mm), for Q about 4.1/3" (110 mm), for S about 3.5/64" (78 mm), for U and G about 3.5/8" (95 mm) and for the type E about 4.1/64" (102 mm).

For a dynamometer with 1100 lb. or 2200 lb. capacity, the types MA and MB are used. These have spring assemblies for 1100 lb. or 2200 lb., arranged in type M housings.

The dynamometers MA-O can be equipped with 1-3 and the types Q-E with 1-5 microswitches. The electrical connections are made in the terminal box to a numbered connection block.

     
     
   
DATA

Repeatability: ± 0.6% of the max. capacity.

Max. Contact Load: 250 VAC, 500 VA, 3A.

Max. Cable Area: 4 mm2

The Mechanical Life of the Microswitch: 20 mill. cycles.

    Back to Top  
     
     
Type Cap. Grad. Wt.
lb/
kg
Measurements in inches and (mm)
A B C D E F G H I
WA
NWA
WC
500 kg
5 kN
1100 lb
5 kg
50 N
10 lb
35 lb
16 kg
15-9/16
(395)
12-7/8
(327)
9-7/32
(234)
1-49/64
(45)
1-11/32
(34)
1-57/64
(48)
63/64
(25)
3-25/64
(86)
1-19/64
(33)
WB
NWB
WD
1000 kg
10 kN
2200 lb
10 kg
100 N
20 lb
35 lb
16 kg
15-9/16
(395)
12-7/8
(327)
9-7/32
(234)
1-49/64
(45)
1-11/32
(34)
1-57/64
(48)
63/64
(25)
3-25/64
(86)
1-19/64
(33)
WM
NWM
WN
2000 kg
20 kN
4400 lb
20 kg
200 N
50 lb
35 lb
16 kg
15-9/16
(395)
12-7/8
(327)
9-7/32
(234)
1-49/64
(45)
1-11/32
(34)
1-57/64
(48)
63/64
(25)
3-25/64
(86)
1-19/64
(33)
WO
NWO
WP
3000 kg
30 kN
6600 lb
20 kg
200 N
50 lb
35 lb
16 kg
15-9/16
(395)
12-7/8
(327)
9-7/32
(234)
1-49/64
(45)
1-11/32
(34)
1-57/64
(48)
63/64
(25)
3-25/64
(86)
1-19/64
(33)
WQ
NWQ
WR
5000 kg
50 kN
11000 lb
50 kg
500 N
100 lb
53 lb
24 kg
16-1/4
(413)
12-15/16
(329)
9-1/16
(230)
1-49/64
(45)
1-21/32
(42)
2-11/64
(55)
1-3/16
(30)
4-51/64
(122)
1-37/64
(40)
WS
NWS
WT
10000 kg
100 kN
22000 lb
100 kg
1 kN
200 lb
79 lb
36 kg
19-1/2
(495)
15-5/32
(385)
10-15/64
(260)
2-23/64
(60)
2-11/64
(55)
2-9/16
(65)
1-49/64
(45)
5-55/64
(149)
2-13/64
(56)
WU
NWU
WV
20000 kg
200 kN
44000 lb
200 kg
2 kN
500 lb
196 lb
89 kg
26-37/64
(675)
19-7/8
(505)
11-13/16
(300)
4-1/64
(102)
3-11/32
(85)
4-1/16
(103)
2-3/4
(70)
8-31/32
(228)
3-3/16
(81)
WG
NWG
WH
25000 kg
250 kN
55000 lb
200 kg
2 kN
500 lb
196 lb
89 kg
26-37/64
(675)
19-7/8
(505)
11-13/16
(300)
4-1/64
(102)
3-11/32
(85)
4-1/16
(103)
2-3/4
(70)
8-31/32
(228)
3-3/16
(81)
WE
NWE
WF
50000 kg
500 kN
110000 lb
500 kg
5 kN
1000 lb
278 lb
126 kg
22-23/32
(831)
24-27/32
(631)
15-15/64
(387)
4-27/32
(123)
3-15/16
(100)
4-49/64
(121)
3-47/64
(95)
9-7/32
(234)
4-17/32
(115)
     
The pull rod movement at full load is approximately 25/64".
We reserve the right to change without notice.
     
     
TECHNICAL DATA

  Accuracy   ± 0.5% of the max. capacity
  Working Temperature   Max. 140°F (+60°C). If the craneweigher is used above objects emitting strong radiant heat, e.g. in foundries, it should be equipped with the heat radiation shield and machine glass. Machine glass cannot be equipped with max. pointer.
  Tareing   The craneweigher can be tared to approx. 10% of the full scale. To obtain the best accuracy, the craneweigher should be supplied calibrated for a known tare.
  Scale   11-15/16" inclined 20° to facilitate reading from below. The scale is white lacquered with black graduation. It is also available with intermediate graduation.
  Max Deflection   Approx. 330°
  Graduation   The craneweigher can be graduated in kg, kp, N, lb, cwt, etc.
     
     
    Back to Top  
     
© 2003-2008 Unirope Ltd. :: Web Design and Layout :: BAUSTEIN Strategic Design Group Inc.